Solid State Timers
|
|
1. ON DELAY Input voltage application starts preset time delay. At end of delay load turns ON. Remove input voltage to reset.
3. INTERVAL Input voltage application turns load ON and starts preset time interval. At the end of the preset interval, the load turns OFF. Remove input voltage to reset.
4. ONE SHOT Input voltage is continuous. Closing the Initiate switch turns the load ON and starts the preset time delay. At the end of the preset delay the load turns OFF. Reset is automatic.
5. RECYCLE/FLASHER When input voltage is applied the load cycles ON/OFF (reverse sequence available). Equal ON/OFF times. Remove input voltage to reset.
6. PROGRAMMABLE RECYCLE: When input voltage is applied, the load cycles ON-OFF...Reverse sequence available. Unequal ON/OFF times are independently adjustable. Remove input voltage to reset.
7. PERCENT: When input voltage is applied, the load cycles ON-OFF...ON and OFF times are varied inversly by a potentiometer with 2 resistive elements on a common shaft. Increasing the ON time also decreases the off time while holding the total time (ON plus OFF) constant. Remove input voltage to reset.
8. RETRIGGERABLE ONE-SHOT
12. ON DELAY/OFF DELAY
13. DELAYED INTERVAL:
35. PULSED/INTERVAL
55. ALTERNATING:
96. DUAL OUTPUT MOTOR REVERSING:
|
Home
| Solid
State Timers | SS1
Amp Output | SS5,
10, 15a Output | SS10
Amp Relay Output
SS30
Amp Relay Output | E/M
Panel Mount | E/M
Chassis Mount | E/M
Reset Timer
E/M
Power Heads | New
Products | Site Map
Precision Timer Co., Inc.
47 Westbrook Ind Pk Rd. • Westbrook, CT 06498
Ph:
(860) 399-6253 • Toll
Free: (800) 541-8943 • Fax:
(860) 399-5619
E-Mail: info@precisiontimer.com
Copyright
© 2001
Precision Timer Co, Inc.
47 Westbrook Industrial Park Road. Westbrook, CT 06498
Ph: (860) 399-6253
Toll Free: (800) 541-8943
Fax: (860) 399-5619 E-Mail:
info@precisiontimer.com